FleetOpsMaritime Operations
UTC16:29 SIM 中文 Company website Live

HY Pearl Horizon · Compressed Air

SIM-V011 · Cruise Ship · 25 installed systems

Healthy
Simulation data · Read-only monitoring
All systems
VESSEL SYSTEM

Compressed Air

5 installed equipment · 6 running

Healthy0 active alertsLast telemetry 0.4s ago
Starting-air receiver 1 pressure27.3 barGood
Service-air pressure7.4 barGood
Starting-air compressor discharge temperature75.5 °CGood
Starting-air receiver pressure27.3 barGood
READ-ONLY PROCESS

Process flow

Receiver 1 Pressure27.3 bar
Service-air pressure7.4 bar
Start Compressor 1 Discharge temperature75.5 °C
Starting Air Receiver Pressure27.3 bar
INSTALLED ASSETS

Equipment status

5 equipment
EquipmentStatePrimary measurementSecondary
Starting Air Compressor 1start-air-compressor-1RunningStart Compressor 1 Running state Active Available Active
Starting Air Compressor 2start-air-compressor-2StandbyStart Compressor 2 Running state Inactive Available Active
Service Air Compressorservice-air-compressorStandby——
Starting Air Receiver 1receiver-1Standby——
Starting Air Receiver 2receiver-2Standby——
ENGINEERING MEASUREMENTS

Measurements

50 points
MeasurementEquipmentValueData QualityUpdated
Running stateams.air_compressor.1.runningAms Air Compressor 1Active Good0.4s ago
Availableams.air_compressor.1.availableAms Air Compressor 1Active Good0.4s ago
Tripams.air_compressor.1.tripAms Air Compressor 1Inactive Good0.4s ago
Suction pressureams.air_compressor.1.suction_pressure_barAms Air Compressor 17.5 barGood0.4s ago
Discharge pressureams.air_compressor.1.discharge_pressure_barAms Air Compressor 119.5 barGood0.4s ago
Temperatureams.air_compressor.1.temperature_cAms Air Compressor 183.1 °CGood0.4s ago
Running hoursams.air_compressor.1.running_hours_hAms Air Compressor 151,530.5 hGood0.4s ago
Running stateams.air_compressor.2.runningAms Air Compressor 2Active Good0.4s ago
Availableams.air_compressor.2.availableAms Air Compressor 2Active Good0.4s ago
Tripams.air_compressor.2.tripAms Air Compressor 2Inactive Good0.4s ago
Suction pressureams.air_compressor.2.suction_pressure_barAms Air Compressor 28.4 barGood0.4s ago
Discharge pressureams.air_compressor.2.discharge_pressure_barAms Air Compressor 222.6 barGood0.4s ago
Temperatureams.air_compressor.2.temperature_cAms Air Compressor 288.2 °CGood0.4s ago
Running hoursams.air_compressor.2.running_hours_hAms Air Compressor 256,829.9 hGood0.4s ago
Running stateams.air_compressor.3.runningAms Air Compressor 3Active Good0.4s ago
Availableams.air_compressor.3.availableAms Air Compressor 3Active Good0.4s ago
Tripams.air_compressor.3.tripAms Air Compressor 3Inactive Good0.4s ago
Suction pressureams.air_compressor.3.suction_pressure_barAms Air Compressor 38.5 barGood0.4s ago
Discharge pressureams.air_compressor.3.discharge_pressure_barAms Air Compressor 323.4 barGood0.4s ago
Temperatureams.air_compressor.3.temperature_cAms Air Compressor 382.3 °CGood0.4s ago
Running hoursams.air_compressor.3.running_hours_hAms Air Compressor 344,759.6 hGood0.4s ago
Running stateams.air_compressor.4.runningAms Air Compressor 4Active Good0.4s ago
Availableams.air_compressor.4.availableAms Air Compressor 4Active Good0.4s ago
Tripams.air_compressor.4.tripAms Air Compressor 4Inactive Good0.4s ago
Suction pressureams.air_compressor.4.suction_pressure_barAms Air Compressor 47.1 barGood0.4s ago
Discharge pressureams.air_compressor.4.discharge_pressure_barAms Air Compressor 419.7 barGood0.4s ago
Temperatureams.air_compressor.4.temperature_cAms Air Compressor 484.2 °CGood0.4s ago
Running hoursams.air_compressor.4.running_hours_hAms Air Compressor 445,789.6 hGood0.4s ago
Running stateams.air_compressor.5.runningAms Air Compressor 5Active Good0.4s ago
Availableams.air_compressor.5.availableAms Air Compressor 5Active Good0.4s ago
Tripams.air_compressor.5.tripAms Air Compressor 5Inactive Good0.4s ago
Suction pressureams.air_compressor.5.suction_pressure_barAms Air Compressor 57.0 barGood0.4s ago
Discharge pressureams.air_compressor.5.discharge_pressure_barAms Air Compressor 519.8 barGood0.4s ago
Temperatureams.air_compressor.5.temperature_cAms Air Compressor 5103.0 °CGood0.4s ago
Running hoursams.air_compressor.5.running_hours_hAms Air Compressor 556,693.4 hGood0.4s ago
Starting Air Receiver Pressureams.starting_air_receiver_pressure_barStarting Air Receiver27.3 barGood0.4s ago
Start Compressor 1 Running stateair.start_compressor.1.runningStarting Air Compressor 1Active Good0.4s ago
Availableair.start_compressor.1.availableStarting Air Compressor 1Active Good0.4s ago
Tripair.start_compressor.1.tripStarting Air Compressor 1Inactive Good0.4s ago
Start Compressor 1 Discharge temperatureair.start_compressor.1.discharge_temp_cStarting Air Compressor 175.5 °CGood0.4s ago
Start Compressor 1 Running hoursair.start_compressor.1.running_hours_hStarting Air Compressor 15,049.0 hGood0.4s ago
Start Compressor 2 Running stateair.start_compressor.2.runningStarting Air Compressor 2Inactive Good0.4s ago
Availableair.start_compressor.2.availableStarting Air Compressor 2Active Good0.4s ago
Tripair.start_compressor.2.tripStarting Air Compressor 2Inactive Good0.4s ago
Start Compressor 2 Discharge temperatureair.start_compressor.2.discharge_temp_cStarting Air Compressor 228.0 °CGood0.4s ago
Start Compressor 2 Running hoursair.start_compressor.2.running_hours_hStarting Air Compressor 25,489.0 hGood0.4s ago
Receiver 1 Pressureair.receiver_1_pressure_barAir System27.3 barGood0.4s ago
Receiver 2 Pressureair.receiver_2_pressure_barAir System26.9 barGood0.4s ago
Service-air pressureair.service_air_pressure_barAir System7.4 barGood0.4s ago
Control-air pressureair.control_air_pressure_barAir System6.8 barGood0.4s ago
The monitoring view encountered an error. Reload×

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.