FleetOpsMaritime Operations
UTC16:05 SIM 中文 Company website Live

HY Pearl Horizon · Electrical

SIM-V011 · Cruise Ship · 25 installed systems

Healthy
Simulation data · Read-only monitoring
All systems
VESSEL SYSTEM

Electrical

4 installed equipment · 0 running

Healthy0 active alertsLast telemetry 0.8s ago
MSB A active power3.67 MWGood
MSB B active power3.53 MWGood
MSB A insulation resistance868.1 kΩGood
ENERGY DISTRIBUTION

Electrical single-line

Monitoring only
Electrical single-line diagram Read-only generator, main switchboard, bus tie, shore power and emergency bus topology. G DG1 1.44 MW · 67% G DG2 1.44 MW · 67% G DG3 1.44 MW · 67% G DG4 1.44 MW · 67% G DG5 1.44 MW · 67% MSB A · 11,000 V · 3,673 kW MSB B · 11,000 V · 3,529 kW Bus Tie Shore Power EG Emergency Generator Emergency Switchboard · 440 V A · 5 feeders B · 11 feeders
INSTALLED ASSETS

Equipment status

4 equipment
EquipmentStatePrimary measurementSecondary
Main Switchboard AMSB-AStandbyVoltage 11,000.0 VCurrent 209.6 A
Main Switchboard BMSB-BStandbyVoltage 11,000.0 VCurrent 201.4 A
Bus Tiebus-tieStandby——
Shore Connectionshore-connectionStandbyVoltage 0.0 VFrequency 0.0 Hz
ENGINEERING MEASUREMENTS

Measurements

131 points
MeasurementEquipmentValueData QualityUpdated
Voltageelec.msb_a.voltage_vMain Switchboard A11,000.0 VGood0.8s ago
Currentelec.msb_a.current_aMain Switchboard A209.6 AGood0.8s ago
Frequencyelec.msb_a.frequency_hzMain Switchboard A60.0 HzGood0.8s ago
Active powerelec.msb_a.active_power_kwMain Switchboard A3.67 MWGood0.8s ago
Reactive powerelec.msb_a.reactive_power_kvarMain Switchboard A734.7 kvarGood0.8s ago
Power factorelec.msb_a.power_factorMain Switchboard A0.9 ratioGood0.8s ago
Thdelec.msb_a.thd_pctMain Switchboard A2.5 %Good0.8s ago
Insulation Resistanceelec.msb_a.insulation_resistance_kohmMain Switchboard A868.1 kΩGood0.8s ago
Voltageelec.msb_b.voltage_vMain Switchboard B11,000.0 VGood0.8s ago
Currentelec.msb_b.current_aMain Switchboard B201.4 AGood0.8s ago
Frequencyelec.msb_b.frequency_hzMain Switchboard B60.0 HzGood0.8s ago
Active powerelec.msb_b.active_power_kwMain Switchboard B3.53 MWGood0.8s ago
Reactive powerelec.msb_b.reactive_power_kvarMain Switchboard B705.9 kvarGood0.8s ago
Power factorelec.msb_b.power_factorMain Switchboard B0.9 ratioGood0.8s ago
Thdelec.msb_b.thd_pctMain Switchboard B2.5 %Good0.8s ago
Insulation Resistanceelec.msb_b.insulation_resistance_kohmMain Switchboard B764.5 kΩGood0.8s ago
Closedelec.bus_tie.closedDistributionActive Good0.8s ago
Voltageelec.esb.voltage_vDistribution440.0 VGood0.8s ago
Frequencyelec.esb.frequency_hzDistribution60.0 HzGood0.8s ago
Availableelec.emergency_generator.availableDistributionActive Good0.8s ago
Availableelec.shore.availableDistributionInactive Good0.8s ago
Connectedelec.shore.connectedDistributionInactive Good0.8s ago
Voltageelec.dc24.voltage_vDistribution26.0 VGood0.8s ago
Loadelec.ups.load_pctDistribution41.4 %Good0.8s ago
Batteryelec.ups.battery_pctDistribution94.0 %Good0.8s ago
Breaker Closedelec.feeder.01.breaker_closedHotel LoadActive Good0.8s ago
Currentelec.feeder.01.current_aHotel Load1,451.3 AGood0.8s ago
Active powerelec.feeder.01.active_power_kwHotel Load3.03 MWGood0.8s ago
Loadelec.feeder.01.load_pctHotel Load56.5 %Good0.8s ago
Tripelec.feeder.01.tripHotel LoadInactive Good0.8s ago
Qualityelec.feeder.01.qualityHotel LoadActive Good0.8s ago
Breaker Closedelec.feeder.02.breaker_closedHVACActive Good0.8s ago
Currentelec.feeder.02.current_aHVAC1,452.3 AGood0.8s ago
Active powerelec.feeder.02.active_power_kwHVAC3.23 MWGood0.8s ago
Loadelec.feeder.02.load_pctHVAC57.4 %Good0.8s ago
Tripelec.feeder.02.tripHVACInactive Good0.8s ago
Qualityelec.feeder.02.qualityHVACActive Good0.8s ago
Breaker Closedelec.feeder.03.breaker_closedGalleyActive Good0.8s ago
Currentelec.feeder.03.current_aGalley1,382.8 AGood0.8s ago
Active powerelec.feeder.03.active_power_kwGalley3.04 MWGood0.8s ago
Loadelec.feeder.03.load_pctGalley59.2 %Good0.8s ago
Tripelec.feeder.03.tripGalleyInactive Good0.8s ago
Qualityelec.feeder.03.qualityGalleyActive Good0.8s ago
Breaker Closedelec.feeder.04.breaker_closedFresh Water TankActive Good0.8s ago
Currentelec.feeder.04.current_aFresh Water Tank1,413.1 AGood0.8s ago
Active powerelec.feeder.04.active_power_kwFresh Water Tank3.40 MWGood0.8s ago
Loadelec.feeder.04.load_pctFresh Water Tank56.5 %Good0.8s ago
Tripelec.feeder.04.tripFresh Water TankInactive Good0.8s ago
Qualityelec.feeder.04.qualityFresh Water TankActive Good0.8s ago
Breaker Closedelec.feeder.05.breaker_closedSewage PlantActive Good0.8s ago
Currentelec.feeder.05.current_aSewage Plant1,115.8 AGood0.8s ago
Active powerelec.feeder.05.active_power_kwSewage Plant3.06 MWGood0.8s ago
Loadelec.feeder.05.load_pctSewage Plant48.9 %Good0.8s ago
Tripelec.feeder.05.tripSewage PlantInactive Good0.8s ago
Qualityelec.feeder.05.qualitySewage PlantActive Good0.8s ago
Breaker Closedelec.feeder.06.breaker_closedPropulsion MotorActive Good0.8s ago
Currentelec.feeder.06.current_aPropulsion Motor1,361.1 AGood0.8s ago
Active powerelec.feeder.06.active_power_kwPropulsion Motor3.48 MWGood0.8s ago
Loadelec.feeder.06.load_pctPropulsion Motor48.0 %Good0.8s ago
Tripelec.feeder.06.tripPropulsion MotorInactive Good0.8s ago
Qualityelec.feeder.06.qualityPropulsion MotorActive Good0.8s ago
Breaker Closedelec.feeder.07.breaker_closedHotel LoadActive Good0.8s ago
Currentelec.feeder.07.current_aHotel Load1,203.4 AGood0.8s ago
Active powerelec.feeder.07.active_power_kwHotel Load3.38 MWGood0.8s ago
Loadelec.feeder.07.load_pctHotel Load45.5 %Good0.8s ago
Tripelec.feeder.07.tripHotel LoadInactive Good0.8s ago
Qualityelec.feeder.07.qualityHotel LoadActive Good0.8s ago
Breaker Closedelec.feeder.08.breaker_closedHVACActive Good0.8s ago
Currentelec.feeder.08.current_aHVAC1,245.5 AGood0.8s ago
Active powerelec.feeder.08.active_power_kwHVAC3.41 MWGood0.8s ago
Loadelec.feeder.08.load_pctHVAC54.3 %Good0.8s ago
Tripelec.feeder.08.tripHVACInactive Good0.8s ago
Qualityelec.feeder.08.qualityHVACActive Good0.8s ago
Breaker Closedelec.feeder.09.breaker_closedGalleyActive Good0.8s ago
Currentelec.feeder.09.current_aGalley1,415.6 AGood0.8s ago
Active powerelec.feeder.09.active_power_kwGalley3.02 MWGood0.8s ago
Loadelec.feeder.09.load_pctGalley45.4 %Good0.8s ago
Tripelec.feeder.09.tripGalleyInactive Good0.8s ago
Qualityelec.feeder.09.qualityGalleyActive Good0.8s ago
Breaker Closedelec.feeder.10.breaker_closedFresh Water TankActive Good0.8s ago
Currentelec.feeder.10.current_aFresh Water Tank1,369.0 AGood0.8s ago
Active powerelec.feeder.10.active_power_kwFresh Water Tank2.87 MWGood0.8s ago
Loadelec.feeder.10.load_pctFresh Water Tank51.1 %Good0.8s ago
Tripelec.feeder.10.tripFresh Water TankInactive Good0.8s ago
Qualityelec.feeder.10.qualityFresh Water TankActive Good0.8s ago
Breaker Closedelec.feeder.11.breaker_closedSewage PlantActive Good0.8s ago
Currentelec.feeder.11.current_aSewage Plant1,150.3 AGood0.8s ago
Active powerelec.feeder.11.active_power_kwSewage Plant3.26 MWGood0.8s ago
Loadelec.feeder.11.load_pctSewage Plant56.9 %Good0.8s ago
Tripelec.feeder.11.tripSewage PlantInactive Good0.8s ago
Qualityelec.feeder.11.qualitySewage PlantActive Good0.8s ago
Breaker Closedelec.feeder.12.breaker_closedPropulsion MotorActive Good0.8s ago
Currentelec.feeder.12.current_aPropulsion Motor1,137.6 AGood0.8s ago
Active powerelec.feeder.12.active_power_kwPropulsion Motor3.10 MWGood0.8s ago
Loadelec.feeder.12.load_pctPropulsion Motor51.2 %Good0.8s ago
Tripelec.feeder.12.tripPropulsion MotorInactive Good0.8s ago
Qualityelec.feeder.12.qualityPropulsion MotorActive Good0.8s ago
Breaker Closedelec.feeder.13.breaker_closedHotel LoadActive Good0.8s ago
Currentelec.feeder.13.current_aHotel Load1,160.4 AGood0.8s ago
Active powerelec.feeder.13.active_power_kwHotel Load3.57 MWGood0.8s ago
Loadelec.feeder.13.load_pctHotel Load57.5 %Good0.8s ago
Tripelec.feeder.13.tripHotel LoadInactive Good0.8s ago
Qualityelec.feeder.13.qualityHotel LoadActive Good0.8s ago
Breaker Closedelec.feeder.14.breaker_closedHVACActive Good0.8s ago
Currentelec.feeder.14.current_aHVAC1,466.0 AGood0.8s ago
Active powerelec.feeder.14.active_power_kwHVAC2.85 MWGood0.8s ago
Loadelec.feeder.14.load_pctHVAC44.6 %Good0.8s ago
Tripelec.feeder.14.tripHVACInactive Good0.8s ago
Qualityelec.feeder.14.qualityHVACActive Good0.8s ago
Breaker Closedelec.feeder.15.breaker_closedGalleyActive Good0.8s ago
Currentelec.feeder.15.current_aGalley1,414.0 AGood0.8s ago
Active powerelec.feeder.15.active_power_kwGalley3.13 MWGood0.8s ago
Loadelec.feeder.15.load_pctGalley54.7 %Good0.8s ago
Tripelec.feeder.15.tripGalleyInactive Good0.8s ago
Qualityelec.feeder.15.qualityGalleyActive Good0.8s ago
Breaker Closedelec.feeder.16.breaker_closedFresh Water TankActive Good0.8s ago
Currentelec.feeder.16.current_aFresh Water Tank1,160.1 AGood0.8s ago
Active powerelec.feeder.16.active_power_kwFresh Water Tank2.87 MWGood0.8s ago
Loadelec.feeder.16.load_pctFresh Water Tank52.8 %Good0.8s ago
Tripelec.feeder.16.tripFresh Water TankInactive Good0.8s ago
Qualityelec.feeder.16.qualityFresh Water TankActive Good0.8s ago
Apparent powerelec.msb_a.extended.apparent_power_kvaMain Switchboard A3,866.8 kVAGood0.8s ago
Current THDelec.msb_a.extended.thd_current_pctMain Switchboard A3.0 %Good0.8s ago
Loadelec.msb_a.extended.load_pctMain Switchboard A78.5 %Good0.8s ago
Apparent powerelec.msb_b.extended.apparent_power_kvaMain Switchboard B3,715.2 kVAGood0.8s ago
Current THDelec.msb_b.extended.thd_current_pctMain Switchboard B3.1 %Good0.8s ago
Loadelec.msb_b.extended.load_pctMain Switchboard B75.4 %Good0.8s ago
Voltageelec.shore.extended.voltage_vShore Connection0.0 VGood0.8s ago
Frequencyelec.shore.extended.frequency_hzShore Connection0.0 HzGood0.8s ago
Breaker Closedelec.shore.extended.breaker_closedShore ConnectionInactive Good0.8s ago
Synchronization stateelec.shore.extended.synchronizedShore ConnectionInactive Good0.8s ago
The monitoring view encountered an error. Reload×

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.