FleetOpsMaritime Operations
UTC16:09 SIM 中文 Company website Live

HY Sea Harvest · Electrical

SIM-V018 · Factory Trawler · 26 installed systems

Healthy
Simulation data · Read-only monitoring
All systems
VESSEL SYSTEM

Electrical

4 installed equipment · 0 running

Healthy0 active alertsLast telemetry 0.1s ago
MSB A active power1.44 MWGood
MSB B active power1.39 MWGood
MSB A insulation resistance764.4 kΩGood
ENERGY DISTRIBUTION

Electrical single-line

Monitoring only
Electrical single-line diagram Read-only generator, main switchboard, bus tie, shore power and emergency bus topology. G DG1 943 kW · 67% G DG2 943 kW · 67% G DG3 943 kW · 67% MSB A · 6,900 V · 1,443 kW MSB B · 6,900 V · 1,387 kW Bus Tie Shore Power EG Emergency Generator Emergency Switchboard · 440 V A · 4 feeders B · 10 feeders
INSTALLED ASSETS

Equipment status

4 equipment
EquipmentStatePrimary measurementSecondary
Main Switchboard AMSB-AStandbyVoltage 6,900.0 VCurrent 131.3 A
Main Switchboard BMSB-BStandbyVoltage 6,900.0 VCurrent 126.1 A
Bus Tiebus-tieStandby——
Shore Connectionshore-connectionStandbyVoltage 0.0 VFrequency 0.0 Hz
ENGINEERING MEASUREMENTS

Measurements

119 points
MeasurementEquipmentValueData QualityUpdated
Voltageelec.msb_a.voltage_vMain Switchboard A6,900.0 VGood0.1s ago
Currentelec.msb_a.current_aMain Switchboard A131.3 AGood0.1s ago
Frequencyelec.msb_a.frequency_hzMain Switchboard A60.0 HzGood0.1s ago
Active powerelec.msb_a.active_power_kwMain Switchboard A1.44 MWGood0.1s ago
Reactive powerelec.msb_a.reactive_power_kvarMain Switchboard A288.7 kvarGood0.1s ago
Power factorelec.msb_a.power_factorMain Switchboard A0.9 ratioGood0.1s ago
Thdelec.msb_a.thd_pctMain Switchboard A2.3 %Good0.1s ago
Insulation Resistanceelec.msb_a.insulation_resistance_kohmMain Switchboard A764.4 kΩGood0.1s ago
Voltageelec.msb_b.voltage_vMain Switchboard B6,900.0 VGood0.1s ago
Currentelec.msb_b.current_aMain Switchboard B126.1 AGood0.1s ago
Frequencyelec.msb_b.frequency_hzMain Switchboard B60.0 HzGood0.1s ago
Active powerelec.msb_b.active_power_kwMain Switchboard B1.39 MWGood0.1s ago
Reactive powerelec.msb_b.reactive_power_kvarMain Switchboard B277.4 kvarGood0.1s ago
Power factorelec.msb_b.power_factorMain Switchboard B0.9 ratioGood0.1s ago
Thdelec.msb_b.thd_pctMain Switchboard B2.0 %Good0.1s ago
Insulation Resistanceelec.msb_b.insulation_resistance_kohmMain Switchboard B773.5 kΩGood0.1s ago
Closedelec.bus_tie.closedDistributionActive Good0.1s ago
Voltageelec.esb.voltage_vDistribution440.0 VGood0.1s ago
Frequencyelec.esb.frequency_hzDistribution60.0 HzGood0.1s ago
Availableelec.emergency_generator.availableDistributionActive Good0.1s ago
Availableelec.shore.availableDistributionInactive Good0.1s ago
Connectedelec.shore.connectedDistributionInactive Good0.1s ago
Voltageelec.dc24.voltage_vDistribution26.2 VGood0.1s ago
Loadelec.ups.load_pctDistribution45.7 %Good0.1s ago
Batteryelec.ups.battery_pctDistribution93.4 %Good0.1s ago
Breaker Closedelec.feeder.01.breaker_closedPropulsion MotorActive Good0.1s ago
Currentelec.feeder.01.current_aPropulsion Motor1,298.2 AGood0.1s ago
Active powerelec.feeder.01.active_power_kwPropulsion Motor3.51 MWGood0.1s ago
Loadelec.feeder.01.load_pctPropulsion Motor49.8 %Good0.1s ago
Tripelec.feeder.01.tripPropulsion MotorInactive Good0.1s ago
Qualityelec.feeder.01.qualityPropulsion MotorActive Good0.1s ago
Breaker Closedelec.feeder.02.breaker_closedThrusterActive Good0.1s ago
Currentelec.feeder.02.current_aThruster1,304.5 AGood0.1s ago
Active powerelec.feeder.02.active_power_kwThruster3.14 MWGood0.1s ago
Loadelec.feeder.02.load_pctThruster58.3 %Good0.1s ago
Tripelec.feeder.02.tripThrusterInactive Good0.1s ago
Qualityelec.feeder.02.qualityThrusterActive Good0.1s ago
Breaker Closedelec.feeder.03.breaker_closedHVACActive Good0.1s ago
Currentelec.feeder.03.current_aHVAC1,234.1 AGood0.1s ago
Active powerelec.feeder.03.active_power_kwHVAC2.83 MWGood0.1s ago
Loadelec.feeder.03.load_pctHVAC57.0 %Good0.1s ago
Tripelec.feeder.03.tripHVACInactive Good0.1s ago
Qualityelec.feeder.03.qualityHVACActive Good0.1s ago
Breaker Closedelec.feeder.04.breaker_closedPumpsActive Good0.1s ago
Currentelec.feeder.04.current_aPumps1,241.7 AGood0.1s ago
Active powerelec.feeder.04.active_power_kwPumps3.46 MWGood0.1s ago
Loadelec.feeder.04.load_pctPumps50.4 %Good0.1s ago
Tripelec.feeder.04.tripPumpsInactive Good0.1s ago
Qualityelec.feeder.04.qualityPumpsActive Good0.1s ago
Breaker Closedelec.feeder.05.breaker_closedDeck MachineryActive Good0.1s ago
Currentelec.feeder.05.current_aDeck Machinery1,371.8 AGood0.1s ago
Active powerelec.feeder.05.active_power_kwDeck Machinery2.77 MWGood0.1s ago
Loadelec.feeder.05.load_pctDeck Machinery48.3 %Good0.1s ago
Tripelec.feeder.05.tripDeck MachineryInactive Good0.1s ago
Qualityelec.feeder.05.qualityDeck MachineryActive Good0.1s ago
Breaker Closedelec.feeder.06.breaker_closedEssential ServicesActive Good0.1s ago
Currentelec.feeder.06.current_aEssential Services1,280.3 AGood0.1s ago
Active powerelec.feeder.06.active_power_kwEssential Services3.08 MWGood0.1s ago
Loadelec.feeder.06.load_pctEssential Services49.6 %Good0.1s ago
Tripelec.feeder.06.tripEssential ServicesInactive Good0.1s ago
Qualityelec.feeder.06.qualityEssential ServicesActive Good0.1s ago
Breaker Closedelec.feeder.07.breaker_closedPropulsion MotorActive Good0.1s ago
Currentelec.feeder.07.current_aPropulsion Motor1,424.8 AGood0.1s ago
Active powerelec.feeder.07.active_power_kwPropulsion Motor2.79 MWGood0.1s ago
Loadelec.feeder.07.load_pctPropulsion Motor59.0 %Good0.1s ago
Tripelec.feeder.07.tripPropulsion MotorInactive Good0.1s ago
Qualityelec.feeder.07.qualityPropulsion MotorActive Good0.1s ago
Breaker Closedelec.feeder.08.breaker_closedThrusterActive Good0.1s ago
Currentelec.feeder.08.current_aThruster1,378.4 AGood0.1s ago
Active powerelec.feeder.08.active_power_kwThruster3.06 MWGood0.1s ago
Loadelec.feeder.08.load_pctThruster54.5 %Good0.1s ago
Tripelec.feeder.08.tripThrusterInactive Good0.1s ago
Qualityelec.feeder.08.qualityThrusterActive Good0.1s ago
Breaker Closedelec.feeder.09.breaker_closedHVACActive Good0.1s ago
Currentelec.feeder.09.current_aHVAC1,409.1 AGood0.1s ago
Active powerelec.feeder.09.active_power_kwHVAC2.92 MWGood0.1s ago
Loadelec.feeder.09.load_pctHVAC51.8 %Good0.1s ago
Tripelec.feeder.09.tripHVACInactive Good0.1s ago
Qualityelec.feeder.09.qualityHVACActive Good0.1s ago
Breaker Closedelec.feeder.10.breaker_closedPumpsActive Good0.1s ago
Currentelec.feeder.10.current_aPumps1,160.9 AGood0.1s ago
Active powerelec.feeder.10.active_power_kwPumps2.84 MWGood0.1s ago
Loadelec.feeder.10.load_pctPumps45.9 %Good0.1s ago
Tripelec.feeder.10.tripPumpsInactive Good0.1s ago
Qualityelec.feeder.10.qualityPumpsActive Good0.1s ago
Breaker Closedelec.feeder.11.breaker_closedDeck MachineryActive Good0.1s ago
Currentelec.feeder.11.current_aDeck Machinery1,222.1 AGood0.1s ago
Active powerelec.feeder.11.active_power_kwDeck Machinery3.04 MWGood0.1s ago
Loadelec.feeder.11.load_pctDeck Machinery51.3 %Good0.1s ago
Tripelec.feeder.11.tripDeck MachineryInactive Good0.1s ago
Qualityelec.feeder.11.qualityDeck MachineryActive Good0.1s ago
Breaker Closedelec.feeder.12.breaker_closedEssential ServicesActive Good0.1s ago
Currentelec.feeder.12.current_aEssential Services1,232.0 AGood0.1s ago
Active powerelec.feeder.12.active_power_kwEssential Services2.86 MWGood0.1s ago
Loadelec.feeder.12.load_pctEssential Services58.9 %Good0.1s ago
Tripelec.feeder.12.tripEssential ServicesInactive Good0.1s ago
Qualityelec.feeder.12.qualityEssential ServicesActive Good0.1s ago
Breaker Closedelec.feeder.13.breaker_closedPropulsion MotorActive Good0.1s ago
Currentelec.feeder.13.current_aPropulsion Motor1,357.9 AGood0.1s ago
Active powerelec.feeder.13.active_power_kwPropulsion Motor2.91 MWGood0.1s ago
Loadelec.feeder.13.load_pctPropulsion Motor58.5 %Good0.1s ago
Tripelec.feeder.13.tripPropulsion MotorInactive Good0.1s ago
Qualityelec.feeder.13.qualityPropulsion MotorActive Good0.1s ago
Breaker Closedelec.feeder.14.breaker_closedThrusterActive Good0.1s ago
Currentelec.feeder.14.current_aThruster1,493.8 AGood0.1s ago
Active powerelec.feeder.14.active_power_kwThruster3.53 MWGood0.1s ago
Loadelec.feeder.14.load_pctThruster56.5 %Good0.1s ago
Tripelec.feeder.14.tripThrusterInactive Good0.1s ago
Qualityelec.feeder.14.qualityThrusterActive Good0.1s ago
Apparent powerelec.msb_a.extended.apparent_power_kvaMain Switchboard A1,519.4 kVAGood0.1s ago
Current THDelec.msb_a.extended.thd_current_pctMain Switchboard A2.7 %Good0.1s ago
Loadelec.msb_a.extended.load_pctMain Switchboard A78.5 %Good0.1s ago
Apparent powerelec.msb_b.extended.apparent_power_kvaMain Switchboard B1,459.9 kVAGood0.1s ago
Current THDelec.msb_b.extended.thd_current_pctMain Switchboard B2.5 %Good0.1s ago
Loadelec.msb_b.extended.load_pctMain Switchboard B75.4 %Good0.1s ago
Voltageelec.shore.extended.voltage_vShore Connection0.0 VGood0.1s ago
Frequencyelec.shore.extended.frequency_hzShore Connection0.0 HzGood0.1s ago
Breaker Closedelec.shore.extended.breaker_closedShore ConnectionInactive Good0.1s ago
Synchronization stateelec.shore.extended.synchronizedShore ConnectionInactive Good0.1s ago
The monitoring view encountered an error. Reload×

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.