FleetOpsMaritime Operations
UTC16:04 SIM 中文 Company website Live

HY Island Express · Electrical

SIM-V010 · Ro-Pax Ferry · 28 installed systems

Healthy
Simulation data · Read-only monitoring
All systems
VESSEL SYSTEM

Electrical

4 installed equipment · 0 running

Healthy0 active alertsLast telemetry 0.7s ago
MSB A active power2.57 MWGood
MSB B active power2.47 MWGood
MSB A insulation resistance777.0 kΩGood
ENERGY DISTRIBUTION

Electrical single-line

Monitoring only
Electrical single-line diagram Read-only generator, main switchboard, bus tie, shore power and emergency bus topology. G DG1 1.68 MW · 68% G DG2 1.68 MW · 68% G DG3 1.68 MW · 68% MSB A · 6,900 V · 2,575 kW MSB B · 6,900 V · 2,474 kW Bus Tie Shore Power EG Emergency Generator Emergency Switchboard · 440 V A · 4 feeders B · 10 feeders
INSTALLED ASSETS

Equipment status

4 equipment
EquipmentStatePrimary measurementSecondary
Main Switchboard AMSB-AStandbyVoltage 6,900.0 VCurrent 234.2 A
Main Switchboard BMSB-BStandbyVoltage 6,900.0 VCurrent 225.0 A
Bus Tiebus-tieStandby——
Shore Connectionshore-connectionStandbyVoltage 0.0 VFrequency 0.0 Hz
ENGINEERING MEASUREMENTS

Measurements

119 points
MeasurementEquipmentValueData QualityUpdated
Voltageelec.msb_a.voltage_vMain Switchboard A6,900.0 VGood0.7s ago
Currentelec.msb_a.current_aMain Switchboard A234.2 AGood0.7s ago
Frequencyelec.msb_a.frequency_hzMain Switchboard A50.0 HzGood0.7s ago
Active powerelec.msb_a.active_power_kwMain Switchboard A2.57 MWGood0.7s ago
Reactive powerelec.msb_a.reactive_power_kvarMain Switchboard A515.0 kvarGood0.7s ago
Power factorelec.msb_a.power_factorMain Switchboard A0.9 ratioGood0.7s ago
Thdelec.msb_a.thd_pctMain Switchboard A2.6 %Good0.7s ago
Insulation Resistanceelec.msb_a.insulation_resistance_kohmMain Switchboard A777.0 kΩGood0.7s ago
Voltageelec.msb_b.voltage_vMain Switchboard B6,900.0 VGood0.7s ago
Currentelec.msb_b.current_aMain Switchboard B225.0 AGood0.7s ago
Frequencyelec.msb_b.frequency_hzMain Switchboard B50.0 HzGood0.7s ago
Active powerelec.msb_b.active_power_kwMain Switchboard B2.47 MWGood0.7s ago
Reactive powerelec.msb_b.reactive_power_kvarMain Switchboard B494.8 kvarGood0.7s ago
Power factorelec.msb_b.power_factorMain Switchboard B0.9 ratioGood0.7s ago
Thdelec.msb_b.thd_pctMain Switchboard B2.2 %Good0.7s ago
Insulation Resistanceelec.msb_b.insulation_resistance_kohmMain Switchboard B865.5 kΩGood0.7s ago
Closedelec.bus_tie.closedDistributionActive Good0.7s ago
Voltageelec.esb.voltage_vDistribution440.0 VGood0.7s ago
Frequencyelec.esb.frequency_hzDistribution50.0 HzGood0.7s ago
Availableelec.emergency_generator.availableDistributionActive Good0.7s ago
Availableelec.shore.availableDistributionInactive Good0.7s ago
Connectedelec.shore.connectedDistributionInactive Good0.7s ago
Voltageelec.dc24.voltage_vDistribution26.2 VGood0.7s ago
Loadelec.ups.load_pctDistribution42.7 %Good0.7s ago
Batteryelec.ups.battery_pctDistribution94.0 %Good0.7s ago
Breaker Closedelec.feeder.01.breaker_closedHotel LoadActive Good0.7s ago
Currentelec.feeder.01.current_aHotel Load1,488.2 AGood0.7s ago
Active powerelec.feeder.01.active_power_kwHotel Load3.08 MWGood0.7s ago
Loadelec.feeder.01.load_pctHotel Load56.4 %Good0.7s ago
Tripelec.feeder.01.tripHotel LoadInactive Good0.7s ago
Qualityelec.feeder.01.qualityHotel LoadActive Good0.7s ago
Breaker Closedelec.feeder.02.breaker_closedHVACActive Good0.7s ago
Currentelec.feeder.02.current_aHVAC1,200.0 AGood0.7s ago
Active powerelec.feeder.02.active_power_kwHVAC2.80 MWGood0.7s ago
Loadelec.feeder.02.load_pctHVAC45.9 %Good0.7s ago
Tripelec.feeder.02.tripHVACInactive Good0.7s ago
Qualityelec.feeder.02.qualityHVACActive Good0.7s ago
Breaker Closedelec.feeder.03.breaker_closedGalleyActive Good0.7s ago
Currentelec.feeder.03.current_aGalley1,333.7 AGood0.7s ago
Active powerelec.feeder.03.active_power_kwGalley3.47 MWGood0.7s ago
Loadelec.feeder.03.load_pctGalley47.4 %Good0.7s ago
Tripelec.feeder.03.tripGalleyInactive Good0.7s ago
Qualityelec.feeder.03.qualityGalleyActive Good0.7s ago
Breaker Closedelec.feeder.04.breaker_closedFresh Water TankActive Good0.7s ago
Currentelec.feeder.04.current_aFresh Water Tank1,160.9 AGood0.7s ago
Active powerelec.feeder.04.active_power_kwFresh Water Tank2.68 MWGood0.7s ago
Loadelec.feeder.04.load_pctFresh Water Tank58.4 %Good0.7s ago
Tripelec.feeder.04.tripFresh Water TankInactive Good0.7s ago
Qualityelec.feeder.04.qualityFresh Water TankActive Good0.7s ago
Breaker Closedelec.feeder.05.breaker_closedSewage PlantActive Good0.7s ago
Currentelec.feeder.05.current_aSewage Plant1,284.1 AGood0.7s ago
Active powerelec.feeder.05.active_power_kwSewage Plant2.72 MWGood0.7s ago
Loadelec.feeder.05.load_pctSewage Plant47.7 %Good0.7s ago
Tripelec.feeder.05.tripSewage PlantInactive Good0.7s ago
Qualityelec.feeder.05.qualitySewage PlantActive Good0.7s ago
Breaker Closedelec.feeder.06.breaker_closedPropulsion MotorActive Good0.7s ago
Currentelec.feeder.06.current_aPropulsion Motor1,390.7 AGood0.7s ago
Active powerelec.feeder.06.active_power_kwPropulsion Motor3.42 MWGood0.7s ago
Loadelec.feeder.06.load_pctPropulsion Motor59.5 %Good0.7s ago
Tripelec.feeder.06.tripPropulsion MotorInactive Good0.7s ago
Qualityelec.feeder.06.qualityPropulsion MotorActive Good0.7s ago
Breaker Closedelec.feeder.07.breaker_closedHotel LoadActive Good0.7s ago
Currentelec.feeder.07.current_aHotel Load1,125.7 AGood0.7s ago
Active powerelec.feeder.07.active_power_kwHotel Load3.04 MWGood0.7s ago
Loadelec.feeder.07.load_pctHotel Load58.8 %Good0.7s ago
Tripelec.feeder.07.tripHotel LoadInactive Good0.7s ago
Qualityelec.feeder.07.qualityHotel LoadActive Good0.7s ago
Breaker Closedelec.feeder.08.breaker_closedHVACActive Good0.7s ago
Currentelec.feeder.08.current_aHVAC1,126.1 AGood0.7s ago
Active powerelec.feeder.08.active_power_kwHVAC3.56 MWGood0.7s ago
Loadelec.feeder.08.load_pctHVAC59.5 %Good0.7s ago
Tripelec.feeder.08.tripHVACInactive Good0.7s ago
Qualityelec.feeder.08.qualityHVACActive Good0.7s ago
Breaker Closedelec.feeder.09.breaker_closedGalleyActive Good0.7s ago
Currentelec.feeder.09.current_aGalley1,384.8 AGood0.7s ago
Active powerelec.feeder.09.active_power_kwGalley3.39 MWGood0.7s ago
Loadelec.feeder.09.load_pctGalley57.2 %Good0.7s ago
Tripelec.feeder.09.tripGalleyInactive Good0.7s ago
Qualityelec.feeder.09.qualityGalleyActive Good0.7s ago
Breaker Closedelec.feeder.10.breaker_closedFresh Water TankActive Good0.7s ago
Currentelec.feeder.10.current_aFresh Water Tank1,483.4 AGood0.7s ago
Active powerelec.feeder.10.active_power_kwFresh Water Tank3.45 MWGood0.7s ago
Loadelec.feeder.10.load_pctFresh Water Tank52.9 %Good0.7s ago
Tripelec.feeder.10.tripFresh Water TankInactive Good0.7s ago
Qualityelec.feeder.10.qualityFresh Water TankActive Good0.7s ago
Breaker Closedelec.feeder.11.breaker_closedSewage PlantActive Good0.7s ago
Currentelec.feeder.11.current_aSewage Plant1,272.9 AGood0.7s ago
Active powerelec.feeder.11.active_power_kwSewage Plant3.10 MWGood0.7s ago
Loadelec.feeder.11.load_pctSewage Plant49.0 %Good0.7s ago
Tripelec.feeder.11.tripSewage PlantInactive Good0.7s ago
Qualityelec.feeder.11.qualitySewage PlantActive Good0.7s ago
Breaker Closedelec.feeder.12.breaker_closedPropulsion MotorActive Good0.7s ago
Currentelec.feeder.12.current_aPropulsion Motor1,387.1 AGood0.7s ago
Active powerelec.feeder.12.active_power_kwPropulsion Motor2.91 MWGood0.7s ago
Loadelec.feeder.12.load_pctPropulsion Motor48.5 %Good0.7s ago
Tripelec.feeder.12.tripPropulsion MotorInactive Good0.7s ago
Qualityelec.feeder.12.qualityPropulsion MotorActive Good0.7s ago
Breaker Closedelec.feeder.13.breaker_closedHotel LoadActive Good0.7s ago
Currentelec.feeder.13.current_aHotel Load1,491.0 AGood0.7s ago
Active powerelec.feeder.13.active_power_kwHotel Load3.10 MWGood0.7s ago
Loadelec.feeder.13.load_pctHotel Load50.2 %Good0.7s ago
Tripelec.feeder.13.tripHotel LoadInactive Good0.7s ago
Qualityelec.feeder.13.qualityHotel LoadActive Good0.7s ago
Breaker Closedelec.feeder.14.breaker_closedHVACActive Good0.7s ago
Currentelec.feeder.14.current_aHVAC1,418.1 AGood0.7s ago
Active powerelec.feeder.14.active_power_kwHVAC3.38 MWGood0.7s ago
Loadelec.feeder.14.load_pctHVAC50.0 %Good0.7s ago
Tripelec.feeder.14.tripHVACInactive Good0.7s ago
Qualityelec.feeder.14.qualityHVACActive Good0.7s ago
Apparent powerelec.msb_a.extended.apparent_power_kvaMain Switchboard A2,710.4 kVAGood0.7s ago
Current THDelec.msb_a.extended.thd_current_pctMain Switchboard A3.2 %Good0.7s ago
Loadelec.msb_a.extended.load_pctMain Switchboard A78.5 %Good0.7s ago
Apparent powerelec.msb_b.extended.apparent_power_kvaMain Switchboard B2,604.1 kVAGood0.7s ago
Current THDelec.msb_b.extended.thd_current_pctMain Switchboard B2.7 %Good0.7s ago
Loadelec.msb_b.extended.load_pctMain Switchboard B75.4 %Good0.7s ago
Voltageelec.shore.extended.voltage_vShore Connection0.0 VGood0.7s ago
Frequencyelec.shore.extended.frequency_hzShore Connection0.0 HzGood0.7s ago
Breaker Closedelec.shore.extended.breaker_closedShore ConnectionInactive Good0.7s ago
Synchronization stateelec.shore.extended.synchronizedShore ConnectionInactive Good0.7s ago